SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "swepub ;pers:(Larsson Anders);srt2:(1990-1994)"

Sökning: swepub > Larsson Anders > (1990-1994)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Olovsson, Matts, 1958-, et al. (författare)
  • Biotin labelling of chicken antibodies and their subsequent use in ELISA and immunohistochemistry
  • 1993
  • Ingår i: Comparative Immunology, Microbiology & Infectious Diseases. - 0147-9571 .- 1878-1667. ; 16:2, s. 145-152
  • Tidskriftsartikel (refereegranskat)abstract
    • Avian antibodies have many advantages to mammalian antibodies due to the phylogenetic differences between birds and mammals, resulting in an increased sensitivity and a decreased background in many immunological assays. Since the avidin-biotin system is an efficient detection system for antibodies with a high sensitivity, we wanted to investigate the activity and unspecific binding of optimally biotin labelled chicken antibodies in ELISA and immunohistochemistry. We report on the conditions for biotinylation of chicken antibodies and that optimally biotinylated antibodies show a high activity and a low background in both ELISA and immunohistochemistry.
  •  
3.
  •  
4.
  • Lindberg, Lars, et al. (författare)
  • Nitric oxide gives maximal response after coronary artery bypass surgery
  • 1994
  • Ingår i: Journal of Cardiothoracic and Vascular Anesthesia. - : Elsevier BV. - 1532-8422 .- 1053-0770. ; 8:2, s. 182-187
  • Tidskriftsartikel (refereegranskat)abstract
    • The dose-response to inhalation of nitric oxide (NO) after coronary artery bypass surgery was studied in seven patients with normal preoperative lung function and chest radiograms. During postoperative controlled ventilation with PEEP 5 and 10 cmH2O, the patients inhaled NO in concentrations of 2 to 25 ppm, in random order, for 6 to 10 minutes. Hemodynamic and oximetric data were analyzed before, 5 minutes after start of the NO inhalation, and 5 minutes after the cessation. The response was the same at all concentrations; mean pulmonary artery pressure decreased by 11 +/- 1% (P < 0.05) and pulmonary vascular resistance decreased by 22 +/- 2% (P < 0.05). Systemic hemodynamics did not change, but oximetric parameters tended to improve. Changes in PEEP did not affect the response. It is concluded that, in patients who have undergone coronary artery bypass grafting, inhalation of 2 to 25 ppm NO causes a dose-independent decrease in pulmonary artery pressure and pulmonary vascular resistance. In order to investigate the dose-response curve, concentrations lower than 2 ppm of NO must be used.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy